Keeper workflows
Two filter branches need not share flow equally
Reconcile a parallel filter split from branch-specific readings and handle a second packet with only the total.
By FishyMag · Published
Worked hydraulic example · Not a clinical review or treatment recommendation.
Quick answer
The fictional 800 L/h manifold sends 260 L/h through filter A and 540 L/h through filter B: 32.5% and 67.5%. In the second record, 800 L/h is the only observation. Both branch flows are unresolved there.


Figure data and explanation
Original fictional parallel-filter manifold. The bar represents the measured allocation in packet A only.
- Branch A
- 260 L/h is 32.5% of the measured total.
- Branch B
- 540 L/h is 67.5% of the measured total.
- Total only
- No split can be inferred for packet B.
The second packet cannot inherit the first packet’s branch distribution.
Two filters can share connections without sharing flow equally
The teaching system has filters A and B between the same supply and return headers. Parallel paths connect at common junctions; each branch’s head loss depends on its own path, restrictions and flow. The EPA network equations apply continuity at junctions and relate head loss to individual links. They do not justify a 50:50 split from a two-filter inventory.
Finish both records
Packet A contains simultaneous readings in a settled state; packet B belongs to a different configuration and has only its main meter reading.
| Packet | Available readings | Supported conclusion |
|---|---|---|
| A | A 260; B 540; total 800 L/h | Sum agrees with total at stated resolution |
| A | 260 ÷ 800 and 540 ÷ 800 | A 32.5%; B 67.5% |
| B | Total 800 L/h only | A and B individually unresolved |
| B, assumed equal split | 400 plus 400 also sums to 800 | Arithmetically possible, unsupported by observations |
Record the mismatch instead of smoothing it away
If the branch sum and main meter disagree in a real packet, check timestamps, flow direction, omitted connections, changes in storage and each meter’s uncertainty before declaring an error. Do not average unmatched readings into a neat split. The figures here tell where water went during packet A; they do not compare how well either filter performed or prescribe valve changes.
Use your own details
Two filter branches need not share flow equally worksheet
Download the editable text file, fill it in on your device and keep it with the relevant record. This blank worksheet records your information; it does not verify entries or approve treatment.
- Branch inlet and reunion drawing
- Filter identities and operating states
- Measurement points and time window
- Total flow record
- A and B flow records
- Uncertainty and continuity check
- Unsupported split assumptions
Put it into practice
Your checklist
- Keep one measurement row per branch.
- Check branch sum against comparable total.
- Leave the split unresolved when only the total is documented.
Sources and scope
This article distinguishes manufacturer statements from FishyMag’s own workflows and arithmetic examples. Linked formulation records retain their own evidence dates; publishing this article does not refresh those records.
- US EPA EPANET 2.2 manual, network components and hydraulic equations; reviewed November 9, 2026 ↗
- US Bureau of Reclamation Water Measurement Manual, changing flow conditions; reviewed November 9, 2026 ↗
AI-assisted writing and development. Not hands-on product testing or veterinary review. How we publish →
FishyMag reports what manufacturers say, quoted and linked. It does not diagnose illness or recommend a treatment, and it never infers that a product is safe from the absence of a warning — where no statement exists, it says so.
Formulations change. Always read the label on the bottle in your hand, and contact the manufacturer if your tank contains anything valuable or unusual.