Keeper workflows

Two filter branches need not share flow equally

Reconcile a parallel filter split from branch-specific readings and handle a second packet with only the total.

By FishyMag · Published

Worked hydraulic example · Not a clinical review or treatment recommendation.

Quick answer

The fictional 800 L/h manifold sends 260 L/h through filter A and 540 L/h through filter B: 32.5% and 67.5%. In the second record, 800 L/h is the only observation. Both branch flows are unresolved there.

Photograph of pumps, vessels and connected pipes in the Melbourne Aquarium plant room.
Public aquarium filtration equipment at a different scale from the worked example. The photo does not establish which actual branches are parallel or their flows. Resized on a white canvas and converted to WebP. The adapted photograph retains CC BY-SA 3.0. Photo: Peter Halasz (Pengo). Melbourne Aquarium pumps, Pengo · CC BY-SA 3.0.

Two filters can share connections without sharing flow equally

The teaching system has filters A and B between the same supply and return headers. Parallel paths connect at common junctions; each branch’s head loss depends on its own path, restrictions and flow. The EPA network equations apply continuity at junctions and relate head loss to individual links. They do not justify a 50:50 split from a two-filter inventory.

Finish both records

Packet A contains simultaneous readings in a settled state; packet B belongs to a different configuration and has only its main meter reading.

Finish both records: worked table
PacketAvailable readingsSupported conclusion
AA 260; B 540; total 800 L/hSum agrees with total at stated resolution
A260 ÷ 800 and 540 ÷ 800A 32.5%; B 67.5%
BTotal 800 L/h onlyA and B individually unresolved
B, assumed equal split400 plus 400 also sums to 800Arithmetically possible, unsupported by observations

Record the mismatch instead of smoothing it away

If the branch sum and main meter disagree in a real packet, check timestamps, flow direction, omitted connections, changes in storage and each meter’s uncertainty before declaring an error. Do not average unmatched readings into a neat split. The figures here tell where water went during packet A; they do not compare how well either filter performed or prescribe valve changes.

Use your own details

Two filter branches need not share flow equally worksheet

Download the editable text file, fill it in on your device and keep it with the relevant record. This blank worksheet records your information; it does not verify entries or approve treatment.

  1. Branch inlet and reunion drawing
  2. Filter identities and operating states
  3. Measurement points and time window
  4. Total flow record
  5. A and B flow records
  6. Uncertainty and continuity check
  7. Unsupported split assumptions
Download worksheet (.txt)

Put it into practice

Your checklist

  • Keep one measurement row per branch.
  • Check branch sum against comparable total.
  • Leave the split unresolved when only the total is documented.

Sources and scope

This article distinguishes manufacturer statements from FishyMag’s own workflows and arithmetic examples. Linked formulation records retain their own evidence dates; publishing this article does not refresh those records.

AI-assisted writing and development. Not hands-on product testing or veterinary review. How we publish →

FishyMag reports what manufacturers say, quoted and linked. It does not diagnose illness or recommend a treatment, and it never infers that a product is safe from the absence of a warning — where no statement exists, it says so.

Formulations change. Always read the label on the bottle in your hand, and contact the manufacturer if your tank contains anything valuable or unusual.

Continue exploring